出  处:《郑州铁路职业技术学院学报》2022年第4期53-56,共4页Journal of Zhengzhou Railway Vocational and Technical College

摘  要:可视化直流验电接地装置为验电、放电、接地一体化装置,内置电动接地刀闸、直流验电闭锁控制器、放电器、安全管控单元、摄像机等设备,具有远程验电和接地操作、接触网残压自动放电、接触网和接地刀闸运行参数和视频画面实时上传等功能,实现接地操作的全程遥控。针对可视化接地柜的典型故障进行分析和探讨,保障设备平稳工作,进一步提升作业效率。The visual DC electrical grounding device is an integrated device for electrical testing,discharge and grounding,with built-in electric grounding switch,DC electrical testing and locking controller,discharge device,safety control unit,camera and other equipment.It has functions such as remote electrical testing and grounding operation,automatic discharge of catenary residual voltage,real-time uploading of video pictures of operation parameters of catenary and grounding switch,which make completely remote control of grounding operation into reality.The typical faults of the visual grounding cabinet are analyzed and discussed to ensure the smooth operation of the equipment and further improve the working efficiency.