预作用自动喷水灭火系统在数据中心中的应用探讨  被引量:2

Application of pre-action sprinkler system in internet data center

在线阅读下载全文

作  者:翁时超 WENG Shichao(China United Engineering Co.,Ltd.,Hangzhou 310052,China)

机构地区:[1]中国联合工程有限公司,杭州310052

出  处:《给水排水》2022年第S01期394-397,共4页Water & Wastewater Engineering

摘  要:数据中心的办公用房、工具间及走道等非设备运行房属于不允许出现误喷或管道漏水的场合,为确保消防系统的可靠性,这些场所内通常设置预作用自动喷水灭火系统。合理设置预作用自动喷水灭火系统中的电动阀和自动排气阀,将极大缩减系统配水管道的充水时间,提高消防系统的安全性及可靠性。Non-equipment operation rooms such as office rooms,tool rooms and aisles of the data center are places where accidental spray or pipeline leakage is not allowed.To ensure the reliability of the fire protection system,pre-action sprinkler systems are usually installed in these places.Reasonable design of the electric valve and automatic exhaust valve in the pre-action sprinkler system will greatly reduce the water filling time of the water distribution pipeline of the system and improve the safety and reliability of the fire protection system.

关 键 词:预作用自动喷水灭火系统 数据中心 电动阀 自动排气阀 

分 类 号:TU892[建筑科学]

 