检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Zhidu Zhang Jinming Hu Xiao mei Zhang Qiong Xu Mohan Li Cunfeng Wei Long Wei Zhe Wang
机构地区:[1]Beijing Engineering Research Center of Radiographic Techniques and Equipment,Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China [2]School of Nuclear Science and Technology,University of Chinese Academy of Sciences,Beijing 100049,China [3]Jinan Laboratory of Applied Nuclear Science,Jinan 250131,China
出 处:《Radiation Detection Technology and Methods》2020年第3期303-311,共9页辐射探测技术与方法(英文)
基 金:supported by National Key R&D Program of China(Grant No.2016YFC0100400);Science and Tech-nology Service network Initiative of Chinese Academy of Sciences(Grant No.KFJ-STS-QYZD-193);Instrument Developing Project of Chinese Academy of Sciences(Grant No.YZ201511);National Natu-ral Science Foundation of China(Grant No.11975250)
摘 要:Purpose K-edge imaging based on the photon counting detectors(PCDs)is an effective enhanced imaging method because the PCDs are conducive to the K-edge imaging due to the adjustable energy thresholds.The energy bins significantly affect the image quality of the K-edge imaging,but the conventional energy bins used for K-edge imaging are continuous which weaken the K-edge signal and decline the image quality.Hence,how to get a better K-edge signal by the optimized energy bins is the key point for the K-edge imaging based on the PCDs.Method This paper experimentally studied the influence of the energy bins used for the K-edge imaging based on the PCDs.The conventional energy bins were determined by the theoretical-attenuation method(TAM),and the optimized energy bins were determined by the threshold-scan method(TSM).For the phantom and mice imaging,we performed both the K-edge subtraction algorithm and the K-edge decomposition algorithm on the projections obtained by the energy bins which were determined by the TAM and TSM.The image quality was compared using the CNR of the objective area.Results The experimental results showed that the energy bins identified by the TSM had a better performance than the TAM in both imaging methods.The TSM improved the CNR by~39%than the TAM in the phantom results and could better highlight the areas where the contrast agents are enriched(such as the kidney).Conclusions The optimized energy bins can better highlight the K-edge signal than the conventional energy bins which can improve the image quality and have the potential to reduce the amount of the contrast agents.
关 键 词:Experimental study Energy bins K-edge imaging Photon counting detectors MICE
分 类 号:TL7[核科学技术—辐射防护及环境保护]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222