内反射传感方法测量溶液浓度的机理探讨  

MECHANISM TO MEASURE CONCENTRATION OF SOLUTIONS BY INTERAL REFLECTION SENSING METHOD

在线阅读下载全文

作  者:张季熊[1] 周佐平[1] 方渝东 

机构地区:[1]华南理工大学应用物理系,广州510641

出  处:《华南理工大学学报(自然科学版)》1997年第11期44-49,共6页Journal of South China University of Technology(Natural Science Edition)

基  金:国家自然科学基金;广东省自然科学基金资助项目

摘  要:介绍用光学传感方法对溶液浓度进行选择性测量.讨论了光与物质相互作用所产生的反常色散现象;分析了具有吸收谱的物质的复折射率与波长的关系;研究了反射率的衰减及衰减全反射现象.实验结果表明,这种传感方法对溶液浓度的选择性测量是有效的.This paper deals with the selective measurement of solution concentration by using optical sensitive method. The anomalous dispersion which originates from the interaction between light and matter is discussed. The relation of complex refractive index of matter having absorption band and wavelength is analyzed. The attenuation of reflectivity and attenuated total reflection are studied. Experimental results show that the sensing method is feasible to selective detection on concentration measurement.

关 键 词:浓度 选择性测量 全内反射 折射率 

分 类 号:TP212[自动化与计算机技术—检测技术与自动化装置]

 