摘  要:固定式消防泵作为建筑物主要灭火设备之一,它的可靠性尤为重要,其控制器又是消防泵可靠性最薄弱环节之一。本文介绍了GBXXXX-200X《低压开关设备和控制设备固定式消防泵驱动器的控制器》和IEC/TS62091标准的主要内容,包括标准适用范围、固定式消防泵驱动器的控制器的结构、性能及试验方法等。The stationary fire pump is one of the fire control equipments. It is important for the stationary fire pump to operate reliably. However the controller for driver of stationary fire pump is one of the weaker processes in reliability. Introduces main contents of IEC / TS 62091 and national standard GBXXXX-200X Low-voltage switchgear and controlgear-controllersfor drivers of stationary fire pumps. It includes standard application scope,components,performance and test method of controllers. IEC / TS 62091 characterizes the unique features and testing procedure of fire pump controllers in detail. This standard helps to improve the reliability of the integral fire pump.