天然气压缩机中压变频器冷却制水系统技术国产化  被引量:2

Indigenization of deionized water preparation technology for cooling medium-pressure converter of the natural gas compressor

在线阅读下载全文

作  者:牛进龙 孙秀敏[2] 刘光利 陈郁 丁雪红 孙元俊 

机构地区:[1]中国石油兰州化工研究中心,甘肃兰州730060 [2]中国石油兰州石油化工公司工程公司,甘肃兰州730060 [3]中国石油兰州石化分公司化肥厂,甘肃兰州730060

出  处:《石化技术与应用》2007年第4期344-346,共3页Petrochemical Technology & Application

摘  要:筛选出了一种制水剂,并对其进行了改性评价,用改性后的制水剂替代了脱离子罐内原有进口制水剂。3年的运行结果表明,改造后的冷却制水系统运行状况良好,且制水效果优于进口制水剂的技术指标,冷却介质(脱离子水)电导率由0.601μS/cm降至0.200μS/cm所需时间由原来的60 min缩短到20~30 min,且系统运行周期由原来的72 h延长到120 h。A novel agent for preparing deionized water was selected and modified.After evaluated,it was used to replace the imported agent in the deionizer and for 3 years.The results showed that the modified system has been running well,and the performance of deionized water exceeded the technical indices of imported agent.When the conductance ratio of deionized water(coolant) reduced from 0.601μS/cm to 0.200μS/cm,the required time shortened from 60min to 20~30min.And the system operation cycle extended from 72h to 120h.

关 键 词:中压变频器 冷却制水系统 国产化 天然气 脱离子水 电导率 

分 类 号:TQ085[化学工程]

 