Interaction of ions in water system containing copper-zinc alloy for boiler energy saving  被引量:2

在线阅读下载全文

作  者:MING Xing LIANG Jinsheng OU Xiuqin TANG Qingguo DING Yan 

机构地区:[1]Institute of Power Source and Ecomaterials Science,Hebei University of Technology,Tianjin 300130,China

出  处:《Rare Metals》2006年第z1期405-410,共6页稀有金属(英文版)

基  金:This work was financially supported by the Key Technologies R&D Program of Tianjin(No.06YFGZGX02400).

摘  要:Copper-zinc alloy element for boiler energy saving was put in the intake of simulated boiler system to investigate the interaction and transfer of ions in water system both theoretically and experimentally.The fouling was analyzed by scanning electron microscopy(SEM)and energy dispersive X-ray detector(EDX).The results show that the transfer of calcium and magnesium ions in heat-transfer-surface-water system is affected by zinc ions dissolved from the alloy because of primary battery reaction.Some calcium ions of calcium carbonate crystal are replaced by zinc ions,the growth of aragonite crystal nucleus is retarded,and the transition of calcium carbonate from aragonite to calcite is hampered.

关 键 词:copper-zinc alloy calcium carbonate FOULING energy saving BOILER water treatment interaction of ions 

分 类 号:TG146.4[一般工业技术—材料科学与工程]

 