A Study on the Temperature Correlation of B-mode Ultrasonic Image Gray for Noninvasive Temperature Monitoring in Hyperthermia  被引量:3

A Study on the Temperature Correlation of B-mode Ultrasonic Image Gray for Noninvasive Temperature Monitoring in Hyperthermia

在线阅读下载全文

作  者:WU Shui-cai Ren Xin-ying Bai Yan-ping Zeng Yi 

机构地区:[1]Biomedical Engineering Center, Beijing University of Technology, Beijing 100022, China Biomedical Engineering Center, Beijing University of Technology, Beijing 100022, China Biomedical Engineering Center, Beijing University of Technology, Beijing 100022, China Biomedical Engineering Center, Beijing University of Technology, Beijing 100022, China

出  处:《Chinese Journal of Biomedical Engineering(English Edition)》2006年第1期26-30,共5页中国生物医学工程学报(英文版)

基  金:The research was supported by National Nature Science Foundation (30470450); Education Committee Foundation( KP0608200201 ) ; Elitist Foundation( KW5800200351 ) from Beijing City,China.

摘  要:This paper deals with the temperature correlation of gray scale of B-mode ultrasound image from heated tissue. In this study, many in-vitro fresh pig livers are heated in a temperature range from 28 ℃ to 45℃, from which a series of B-mode ultrasonic images of livers were obtained. The gray-value is evaluated from the ultrasound images respectively. A correlation of the mean gray value of the selected regions (12×12 pixels) in B-mode ultrasonic images of liver and its temperature was pointed out. And the experiment results agreed the evaluation well. And it is possible to monitor the tissue temperature changing in hyperthermia using this correlation.This paper deals with the temperature correlation of gray scale of B-mode ultrasound image from heated tissue. In this study, many in-vitro fresh pig livers are heated in a temperature range from 28 ℃ to 45℃, from which a series of B-mode ultrasonic images of livers were obtained. The gray-value is evaluated from the ultrasound images respectively. A correlation of the mean gray value of the selected regions (12×12 pixels) in B-mode ultrasonic images of liver and its temperature was pointed out. And the experiment results agreed the evaluation well. And it is possible to monitor the tissue temperature changing in hyperthermia using this correlation.

关 键 词:B-MODE ultrasound image  TEMPERATURE correlation  HYPERTHERMIA 