检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江大学医学院附属妇产科医院,浙江杭州310006
出 处:《中国现代应用药学》2005年第z2期769-770,共2页Chinese Journal of Modern Applied Pharmacy
摘 要:目的研制替硝唑栓,并制定质量控制方法。方法以聚乙二醇400及6000为基质,用熔融法制备。紫外分光光度法测定该栓剂中替硝唑的含量,测定波长317nm。结果替硝唑在浓度4~20μg·mL^(-1)范围内有良好的线性关系,r=0.9999,平均回收率100.86%,RSD为1.29%(n=9)。结论该制剂制备简便易行,稳定性好,其质量控制方法简单,专属性好,结果准确可靠。OBJECTIVE To prepare tinidazole suppository and establish quality control method.METHOD The suppository were prepared by using PEG-400 and PEG-6000.The tinidazole content in suppository were determined by UV-spectrophometry at317 nm.RESULTS The tinidazole contentration was linear within the range 4~20μg·mL^(-1) with r = 0.9999.The average recovery was 100.86%with RSD 1.29%(n =9).CONCLUTION The suppository can be prepared simply and feasibly.The method of quality control is simple,rapid and accurate.