检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:邝妙欢[1] 林翠杏[2] 刘万里[1] 欧阳文婷[3] 姚少羽[3] 邱瑞芬[1] 钟义富[1]
机构地区:[1]中山大学肿瘤医院检验科,广东广州510060 [2]中山大学肿瘤医院放疗科,广东广州510060 [3]中山大学附属第一医院检验科,广东广州510080
出 处:《国际医药卫生导报》2003年第22期9-10,共2页International Medicine and Health Guidance News
摘 要:目的 对电化学发光免疫法与微粒子酶联免疫法检测血清甲胎蛋白作对比分析。方法 随机抽取150份临床送检的标本,用电化学发光免疫法与微粒子酶联免疫法测试甲胎蛋白的含量,对测试数据进行相关性试验、线性试验、精密度试验、回收试验。结果 两法无显著性差异(P>0.05),但电化学发光免疫法的线性范围较宽(1-980ng/ml),重复性较好(批内CV值3.4%,批间CV值3.5%),回收率较高(97.2%)。结论Objective To evaluate the efficiencies of electrochemiluminescent assay (ECL) andmicroparticle enzyme immunoassy(MEIA)for detecting of the levels of serum AFP .Methods Serum AFPlevels of 150 samples were determined with both ECL and MEIA. The correlation between ECL and MEIA wereassessed, and the assays of linear range, recovery and precision of the two methods were performed andalso evaluated.Results There was no significant difference between ECL and MEIA for detection of thelevels of serum AFP (P>0.05). Overall, however, in comparison with MEIA, ECL had a broader linear range(1-980ng/ml) and a higher precision (the within-run, 3.4%; the between-run, 3.5%) as well as a higheraverage recovery rate (97.2%).Conclusions There was a good correlation between ECL and MEIA fordetermination of the levels of serum AFP. In general, for detecting the levels of serum AFP, ECL wassuperior to MEIA.