隔河岩枢纽泄洪消能试验研究  被引量:3

Experimental Studies on Flood Release and Energy Dissipation for Geheyan Project

在线阅读下载全文

作  者:高仪生[1] 金宝芬[1] 

机构地区:[1]长江科学院水工研究所

出  处:《长江科学院院报》1993年第4期17-24,共8页Journal of Changjiang River Scientific Research Institute

摘  要:本文着重介绍隔河岩枢纽泄洪消能试验研究成果。通过试验,将表孔、深孔、底孔采取平面错开,空间分层,出口采用收缩射流转向的新技术,既满足了泄洪要求,又有较好的消能防冲效果。上述研究成果为设计,施工提供了大量的数据,解决了工程中许多重大的技术难题。This paper provides the experimental results on flood release and energy dissipation for Geheyan Project. By means of model tests, the multiple outlet works, including 7 overflow spillways, 4 medium outlets and 2 bottom outlets, which are situated at different elevation and different location in plane are adopted. The flip buckets with unsymmetrical flaring gate pier for the overflow spillways and unsymmetrical narrow slit for the medium outlets and bottom outlets are used as the dissipators.Using this layout of flood release and energy dissipation, the model tests indicate that the requirement of flood-carrying capacity can be satisfied and the high dissipating rate is obtained. These study results are used in the design of the Geheyan Project.

关 键 词:水利枢纽 消能防冲 试验 

分 类 号:TV653[水利工程—水利水电工程]

 