Precisa活检针在螺旋CT引导下经皮肺穿刺活检诊断肺部病变准确性的分析  被引量:2

Analysis of Diagnostic Accuracy of Percutaneous Lung Biopsy for Pulmonary Diseases with Precisa Needle under MSCT-Guided

在线阅读下载全文

作  者:龙德云[1] 何慎玲 尹满香[1] 庄阜红 张利诚[1] 陈和平[1] 陈明安[1] 

机构地区:[1]武警浙江省总队医院放射科 浙江省嘉兴市妇幼保健院 武警浙江省总队医院病理科 武警浙江省总队医院呼吸科

出  处:《实用放射学杂志》2009年第1期-,共3页Journal of Practical Radiology

摘  要:目的分析影响螺旋CT引导下应用Precisa活检针经皮肺穿刺活检诊断肺部病变准确率的因素。方法回顾性分析87例螺旋CT定位引导下应用Precisa活检针经皮肺穿刺活检资料,对切取病变组织肉眼观与手术病理结果的关系,穿刺的成功率以及并发症进行分析。结果病灶穿刺成功率100%。确定病理诊断78例(89.65%),未明确诊断9例;术后并发症发生率19.5%,其中气胸8例,局部出血5例,咯血2例,经相应处理后缓解。结论螺旋CT引导下用Precisa活检针经皮肺穿刺活检成功率与病理诊断率高,可为临床治疗方法的选择提供可靠依据。Objective To analyze the diagnostic accuracy of percutaneous lung biopsy for pulmonary diseases with Precisa neddle under SCT-guided.Methods The data of percutaneous lung biopsy by using Precisa needle under CT-guided in 87 patients were analyzed retrospectively.The results of surgical pathology were compared with the gross pathological specimens.The successful rate of biopsy and the complications were analysed.Results The successful rate of puncture was 100%.Seventy-eight cases had defined pathological dia...

关 键 词: 穿刺活检 体层摄影术 X线计算机 

分 类 号:R446.8[医药卫生—诊断学]

 