VFT PHASE VOLTAGE MEASUREMENT IN THREE-PHASE ENCLOSED GIS  被引量:1

VFT PHASE VOLTAGE MEASUREMENT IN THREE-PHASE ENCLOSED GIS

在线阅读下载全文

作  者:Zou Jianhua(邹建华) Yue Ziding(岳子丁) Li Yang(李洋) 

机构地区:[1]Systems Engineering Institute, Xi''an Jiaotong University, Xi''an 710049, China. Systems Engineering Institute, Xi''an Jiaotong University, Xi''an 710049, China. Systems Engineering Institute, Xi''an Jiaotong University, Xi''an 710049, China.

出  处:《Academic Journal of Xi'an Jiaotong University》2002年第2期101-108,共8页西安交通大学学报(英文版)

摘  要:The measuring of VFT phase voltage in three-phase enclosed GIS is more complex and difficult than in single-phase ones. There are 3 capacitive sensors in the measuring system, the outputs of which are with a linear relation to the three phase voltages. This linear relation is presented with a factorial matrix. Because each capacitive sensor is coupled with the electric field of three phases (A, B, and C), the electric coupling coefficients are introduced. In order to determine the matrix of electric coupling coefficients, the numerical calculation method can be used. From the discussion on two types of three-phase enclosed GIS bus, i.e. standard arrangement and biased arrangement, the dominant electric coupling coefficients are named, which can be simply and approximately calculated by an analytic expression. Finally, as an example, the waveforms of VFT phase voltage generated on a three-phase enclosed GIS bus model are displayed. When a capacitive sensor is located at the ’shortest point’ of phase A (or B, or C), the VFT phase voltage V A (or V B, or V C) can almost be measured by that capacitive sensor alone.The measuring of VFT phase voltage in three-phase enclosed GIS is more complex and difficult than in single-phase ones. There are 3 capacitive sensors in the measuring system, the outputs of which are with a linear relation to the three phase voltages. This linear relation is presented with a factorial matrix. Because each capacitive sensor is coupled with the electric field of three phases (A, B, and C), the electric coupling coefficients are introduced. In order to determine the matrix of electric coupling coefficients, the numerical calculation method can be used. From the discussion on two types of three-phase enclosed GIS bus, i.e. standard arrangement and biased arrangement, the dominant electric coupling coefficients are named, which can be simply and approximately calculated by an analytic expression. Finally, as an example, the waveforms of VFT phase voltage generated on a three-phase enclosed GIS bus model are displayed. When a capacitive sensor is located at the 'shortest point' of phase A (or B, or C), the VFT phase voltage V A (or V B, or V C) can almost be measured by that capacitive sensor alone.

关 键 词:gas insulated substation(GIS) very fast transients(VFT) VOLTAGE MEASUREMENT electric field ANALYTIC expression MEASUREMENT apparatus VFT phase VOLTAGE wave 

分 类 号:TN933[电子电信—信号与信息处理]

 