摘  要:采用计算流体力学(CFD)的方法对300 mm口径的均速管流量计的内部流动进行了数值仿真,湍流模型应用标准k-ε模型,应用有限体积法对控制方程离散和求解.通过计算得出均速管流量计在几种长度不同的前直管段条件下的流量系数;还研究了流量系数与雷诺数的关系,得出流量计的流量系数随着雷诺数增加有上升的趋势.最后,对未充分发展段的流量系数进行了修正,得出了流量系数与雷诺数之间的三次拟合曲线,以此可将未充分发展段的测量值修正为充分发展后的数值,以实现在管道长度不足的情况下得到较为精确的测量值.The flow in an annubar flowmeter with diameter of 300 mm was numerically simulated by the method of computational fluid dynamics(CFD).A k-ε based model of turbulence was applied to solve the problem.The control equations were discretized with the finite volume method.The flow coefficients of annubar flowmeter in several different lengths of straight pipe before were calculated.The relationship between the flow coefficient and the Reynolds number was studied.A trend of a rising flow coefficient of flowmeter ...