用废变压器油吸收废气中的二甲苯  被引量:4

Absorption of Xylene in Waste Gas Using Spent Transformer Oil

在线阅读下载全文

作  者:焦昭杰[1] 余成洲[1] 白云[1] 李川[1] 

机构地区:[1]重庆工商大学废油资源化技术与装备教育部工程研究中心,重庆400067

出  处:《化工环保》2010年第2期113-116,共4页Environmental Protection of Chemical Industry

基  金:重庆市科技成果转化项目(KJZH08212);重庆市教委科学技术研究项目(KJ090817)

摘  要:以废变压器油作为吸收剂对二甲苯废气进行吸收处理,考察了影响二甲苯气体去除率的因素。实验结果表明:二甲苯废气流量为350 L/h、废变压器油喷淋量为40 L/h、进口二甲苯废气平日质量浓度为935 mg/m^3、吸收温度为18℃、吸收时间为50 min时,出口二甲苯气体质量浓度为35 mg/m^3,二甲苯去除率高达96.3%,小于GB16297—1996《大气污染物综合排放标准》中二甲苯质量浓度90 mg/m^3的排放标准。Spent transformer oil was used as absorbent in the treatment of xylene-containing waste gas.The factors affecting the xylene removal rate were studied.When the waste gas flow is 350 L/h, the spray flow of spent transformer oil is 40 L/h,the average mass concentration of xylene in the inlet gas is 935 mg/m^3,the absorption temperature is 18℃and the absorption time is 50 min,the mass concentration of xylene in the exit gas is 35 mg/m^3 with 96.3%of the xylene removal rate,which is less than 90 mg/m^3 of the emission standard in GB16297-1996.

关 键 词:变压器油 二甲苯 废气处理 综合利用 

分 类 号:X78[环境科学与工程—环境工程] X322

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象