钢管混凝土叠合柱式桥墩受力性能分析  被引量:6

Analysis of Mechanical Behavior of CFST and Concrete Composite Column Pier

在线阅读下载全文

作  者:曾彦[1] 曾勇[2] 赵顺波[1] 

机构地区:[1]华北水利水电学院土木与交通学院,河南郑州450011 [2]河南世纪博通工程咨询有限公司,河南郑州450008

出  处:《世界桥梁》2010年第2期52-54,58,共4页World Bridges

摘  要:为减小桥墩阻水面积,跨南水北调中线工程主干渠的大油村北桥2号墩墩身采用圆形钢管混凝土叠合柱。采用有限元法进行计算分析,研究叠合柱钢管壁厚与轴向应力比率、弯曲应力比率、抗剪应力比率和组合应力比率、荷载下位移及自振周期等因素的影响规律。结果表明,叠合柱能以较小的直径满足既定承载能力的要求,比普通混凝土桩柱式结构具有更好的经济性和抗震性能。To reduce the water resistance area of bridge pier,the intermediate pier of the Dayoucun North Bridge crossing the trunk cannel of the Central Line of the South-to-North Water Diversion Project was designed as a circular concrete-filled steel tube(CFST) and concrete composite column pier.The finite element method was used to calculate,analyze and study the influential laws of several factors like the steel tube wall thickness and axial stress ratio,bending stress ratio,shear stress ratio,combined stress rat...

关 键 词:桥墩 钢管混凝土结构 叠合柱 承载力 抗震 有限元法 

分 类 号:U441[建筑科学—桥梁与隧道工程]

 