摘 要:目的探讨粪石性肠梗阻的多层螺旋CT诊断价值。方法回顾性分析经手术证实的13例粪石性肠梗阻的CT表现。结果①肠梗阻征象13例(占13/13),病变部位:空肠梗阻2例(占2/13),回肠下段梗阻8例(占8/13),乙状结肠梗阻3例(占3/13)。②粪球征(即蜂窝状气泡征)13例(占13/13),单发者6例(占6/13),多发者7例(占7/13),长径3~10cm,平均5.5cm。③双环征2例(占2/13)。④肠系膜血管漩涡征1例(占1/13)。⑤腹膜炎征象1例(占1/13)。结论粪球征为粪石性肠梗阻特征性表现,CT扫描是术前诊断本病的主要手段。Objective To explore the diagnostic value of multislice spiral CT in bezoar ileus.Methods CT performance of 13 cases with bezoar ileus confirmed by operations was retrospectively analyzed.Results ①Ileus sign was in 13 cases(13/13),obstruction site:jejunum obstruction in 2 cases(2/13),lower segment ileal obstruction in 8 cases(8/13),sigmoid colon obstruction in 3 cases(3/13).②Bezoar sign that seemed honeycomb with air bubble inside was in 13 cases(13/13),7 cases with multiple bezoars(7/13),6 cases with singl...