检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Li-Juan Wang1,2,Yu-Hai Tang1,Bao-Ping Li,Hong-Lang Liu1,Jing-Feng Yi11. Institute of Analytical Sciences,School of Sciences 2. Medical School,Xi’an Jiaotong University,Xi’an 710061,China.
出 处:《Journal of Pharmaceutical Analysis》2010年第2期91-96,共6页药物分析学报(英文版)
基 金:supported by Xi'an Jiaotong University (08140012)
摘 要:Objective To develop a rapid,simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol,atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL,1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL,respectively,with the detection limits of 5.0×10-8g/mL,7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3),respectively,and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol,atenolol and propranolol were 3.57%,2.21% and 2.26%,respectively. Conclusion The developed method is sensitive,accurate,rapid and of low cost. And it can be applied to determine bisoprolol,atenolol and propranolol in pharmaceutical preparations.Objective To develop a rapid,simple and sensitive chemiluminescence method for the determination of three β-blockers (bisoprolol,atenolol and propranolol). Methods The chemiluminescence of cerium (Ⅳ)-sulfite system was obviously sensitized by adding anyone of three β-blockers in acid media. A new chemiluminescence method was set up by combining with flow-injection technique and used to determine the three β-blockers. Results Good linear ranges were obtained at the concentrations of 2.0×10-7g/mL-4.0×10-5g/mL,1.0×10-7g/mL-3.0×10-5g/mL and 7.0×10-7g/mL-1.0×10-5g/mL,respectively,with the detection limits of 5.0×10-8g/mL,7.0×10-8g/mL and 5.0×10-8g/mL (S/N=3),respectively,and the relative standard deviations for 11 times consecutive injections of 1.0×10-6g/mL bisoprolol,atenolol and propranolol were 3.57%,2.21% and 2.26%,respectively. Conclusion The developed method is sensitive,accurate,rapid and of low cost. And it can be applied to determine bisoprolol,atenolol and propranolol in pharmaceutical preparations.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49