臭氧接触池的计算流体力学模拟  被引量:1

Simulation of computational fluid dynamics in ozone contactor

在线阅读下载全文

作  者:王静[1] 邓保庆[1] 陆丽[1] 李勋栋[1] 

机构地区:[1]上海理工大学环境与建筑学院,上海200093

出  处:《水资源与水工程学报》2012年第1期139-141,共3页Journal of Water Resources and Water Engineering

摘  要:臭氧接触池的水力特性直接影响着微生物消毒效果。利用计算流体力学(CFD)技术,采用欧拉多相流模型和标准k-ε湍流模型对单管臭氧接触池内的流场进行数值模拟。结果表明:单管式臭氧接触池内臭氧分布比较均匀,基本上没有"死区"现象的产生,可以保证较高的消毒效率,但是气体气泡大量聚集在接触池出口槽下方。模拟结果对单管式臭氧接触池的优化有一定的借鉴作用。The hydraulic characteristic of ozone contactor has a great impact on the disinfection effect of microorganism.Computational fluid dynamics(CFD) technique was used to simulate the flow field of a single-column ozone contactor.The Eulerian multiphase model and the standard k-ε turbulent model were used in the simulation.The results show that ozone distribution is relatively uniform in the single-column contactor.In general,there does not exist the phenomenon of 'dead zone',which helps to guarantee high disinfection efficiency.However,gas bubble was found to accumulate underneath the outlet trough.The results offer a sample for optimizing the ozonation system.

关 键 词:计算流体力学 臭氧接触池 微生物消毒 

分 类 号:TV131.4[水利工程—水力学及河流动力学] O35[理学—流体力学]

 