检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:梁运兴
机构地区:[1]佛山南海电力设计院工程有限公司,广东佛山528200
出 处:《电力学报》2012年第4期300-305,共6页Journal of Electric Power
摘 要:以500 kV德宏紧凑型输电线路为例,分析了其可能采用的导线型号、分裂方式和导线排列方式。采用国际公认的、经过实际工程验证且广泛使用的计算分析方法,研究了高海拔地区条件下,改变导线排列方式、导线型号以及导线分裂间距时,线路导线表面最大电位梯度和无线电干扰的横向分布水平。根据计算结果,确定了满足无线电干扰水平的导线排列方式、导线型号和导线分裂间距。This paper takes the 500 kV Dehong compact-type transmission line as the example to analyze the possible conductor type,conductor splitting spacing and conductor arrangement.The internationally accepted and verified computation methods are adopted to study the maximum electric potential gradient of conductor surface and radio interference under different conditions of conductor arrangement,conductor type and the conductor splitting spacing in high altitude localities.According to the calculation results,the conductor arrangement,conductor type and conductor splitting spacing are determined which are suit for radio interference level.
关 键 词:输电线 高海拔 紧凑型线路 无线电干扰 大电位梯度 导线排列方式