反渗透-电去离子复合处理水中Ni^(2+)研究  被引量:2

Combined RO-EDI process for treatment of nickel in water

在线阅读下载全文

作  者:郑颖韩[1] 吴昊[1] 陈晟颖[1] 陈雪明[1] 

机构地区:[1]浙江大学环境与资源学院,浙江杭州310058

出  处:《浙江大学学报(理学版)》2012年第1期85-88,共4页Journal of Zhejiang University(Science Edition)

摘  要:考察了不同条件下反渗透-电去离子(RO-EDI)复合处理水中Ni2+的效果.实验结果表明,此复合技术具有良好的净化效率,可将Ni2+质量浓度由原先的200mg.L-1降至0.5mg.L-1以下.合适的操作条件为RO压力1.5MPa;RO浓缩回收液Ni2+质量浓度1600mg.L-1;EDI电流密度7.5A.cm-2;EDI水力停留时间4min.The combined reverse osmosis and electrodeionization(RO-EDI) process was used for treating nickel in water under different operational conditions.Experimental results showed that this combined process had high efficiency in purifying the nickel-containing wastewater.It could reduce the Ni2+ concentration from initial 200 mg·L-1 to lower than 0.5 mg·L-1.The optimum operational conditions are: a pressure of 1.5 MPa for RO;a Ni2+ concentration of 1600 mg·L-1 in the RO concentrate;and a current density of 7.5 A·cm-2 and a hydraulic retention time of 4 min for EDI.

关 键 词: 反渗透 电去离子 

分 类 号:X703[环境科学与工程—环境工程]

 