检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈献春[1] 陈宇[1] 张锦坤[1] 蒋孝科[1] 张民赦[1]
机构地区:[1]福建省电力有限公司电力科学研究院,福建福州350007
出 处:《电力与电工》2012年第2期45-47,57,共4页Electric Power and Electrical Engineering
摘 要:某电厂300 MW循环流化床锅炉自投产以来,由于空气预热器蒸汽吹灰效果不佳,空气预热器管排灰垢不断积累,排烟温度和引风机电流持续升高,机组经济性指标不断下降。改装燃气脉冲吹灰器后,锅炉排烟温度和引风机电流比较稳定,且比采用蒸汽吹灰器的参数大幅降低,锅炉效率和厂用电率等经济指标良好,节能效果明显。After commercial running of a 300MW CFB boiler,due to air preheater steam soot-blowing effect is not obvious,ash continued to accumulate at the air preheater tube row,exhaust gas temperature and draught fan current continues to rise,the unit economy index dropped ceaselessly.After modification of gas soot-blower,the exhaust gas temperature and the draught fan current were relatively stable and greatly reduced compared with the steam soot-blower.The efficiency of the boiler and auxiliary power consumption rate and others economic indicators are good,and energy conservation effect are obvious.
关 键 词:300MW循环流化床锅炉 空气预热器 蒸汽吹灰器 燃气脉冲吹灰器
分 类 号:TK2[动力工程及工程热物理—动力机械及工程]