检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张小敏[1] 马呈霞[1] 钱康[1] 夏明[2] 张世才[1] 郭涛[1] 葛智平[1] 孙頔 郭钰锋[3]
机构地区:[1]甘肃电力科学研究院,甘肃兰州730050 [2]北京国电智深控制技术有限公司,北京102200 [3]哈尔滨工业大学电气工程及自动化学院,黑龙江哈尔滨150001
出 处:《热力发电》2012年第7期86-88,91,共4页Thermal Power Generation
摘 要:通过对某台300MW机组汽轮机并网运行工况进行仿真,分析了该机在高负荷工况下回热系统抽汽效应对汽轮机频率调节的影响。分析表明,抽汽逆止阀开度为100%时为额定功率,开度为50%时功率增加约0.5%,开度为0时功率增加到7%。抽汽逆止阀开度变化对汽轮机功率为非线性影响,抽汽逆止阀全关即切除回热抽汽能最大限度地提高机组功率。To investigate the impact of steam reheating amount variation of regenerators on frequency adjustment in steam turbine that runs with high load,grid-connected condition of the turbine for a 300 MW unit was simulated.Results show that,the turbine output is at rated value when the extraction check valve is fully opened;it increases by about 0.5% when the valve is half opened and by 7% when fully closed.The extraction check valve opening change has a non liner effect on the turbine output.Fully closing the valve,namely cutting off the regenerative extraction,can improve the unit output as high as possible.
关 键 词:300 MW机组 汽轮机 回热系统 抽汽 逆止阀 频率调节
分 类 号:TK284.1[动力工程及工程热物理—动力机械及工程]