检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]韶关发电厂,广东韶关512132
出 处:《热力发电》2013年第7期142-143,146,共3页Thermal Power Generation
摘 要:韶关发电厂2×300MW机组改扩建成2×600MW机组过程中,原全离子交换锅炉补给水处理系统不能满足新机组要求,故采用超滤(UF)+反渗透(RO)+电除盐(EDI)的全膜锅炉补给水处理技术。实际应用表明,全膜水处理系统出水电导率≤0.15μS/cm,SiO2含量≤10μg/L,满足锅炉补给水水质要求;制水成本约2.69元/t,较原系统降低0.11元/t;具有环保、节能、占地小、操作简单等优点。The 2×300MW units in Shaoguang Power Plant was enlarged to 2×600MW units,but the original boiler make-up water treatment system with total ion change can not satisfy the requirement of newly built units.Therefore,the integrated membrane boiler make-up water treatment technology combined with ultra-filtration(UF),reverse osmosis(RO)and electrodeionization(EDI)technologies was applied.The technological process and major equipments of this water treatment system were presented,and the operation cost was analyzed.The practical application indicated that,the conductivity of the effluent from the integrated membrane water treatment system was lower than 0.15μS/cm,and the SiO2content in that was below 10g/L,which met the needs of the boiler make-up water quality;the water preparation cost was 2.69yuan/t,about 0.11 yuan/t lower than that of the original system;this new system also saved energy,occupied small area,be friendly to the environment and simple operation.
关 键 词:全离子交换 全膜水处理 补给水处理 超滤 反渗透 电除盐
分 类 号:TK223.5[动力工程及工程热物理—动力机械及工程]