超超临界二次再热发电机组热经济性分析  被引量:25

Thermal economic analysis on an ultra supercritical unit with second reheat cycle

在线阅读下载全文

作  者:谷雅秀[1] 王生鹏[2] 杨寿敏[2] 朱宝田[2] 

机构地区:[1]长安大学环境科学与工程学院,陕西西安710054 [2]西安热工研究院有限公司,陕西西安710032

出  处:《热力发电》2013年第9期7-9,15,共4页Thermal Power Generation

基  金:国家自然科学基金(51106014)

摘  要:在一次再热机组的主蒸汽压力、主蒸汽温度、再热蒸汽温度保持不变的基础上,采用二次再热可降低汽轮机的热耗率,提高机组效率。以某参数为26.25MPa/600℃/600℃/600℃超超临界1 000MW机组为例,对其进行一次再热与二次再热循环下的各热经济指标对比发现,1 000 MW负荷工况下,二次再热机组汽轮机热耗率比一次再热机组热耗率降低了92kJ/(kW·h),供电煤耗率降低了3.47g/(kW·h),机组净效率提高了0.57%。On the basis of keeping the main steam pressure and temperature and reheat steam temperature of the unit with single reheat cycle constant,applying second reheat cycle can reduce the heat consumption rate and enhance the unit efficiency.Taking an ultra supercritical 1 000MW unit with double reheat cycles and steam parameter of 26.25MPa/600℃/600℃/600℃as the example,comparison of the thermal economic indices of unit running with single reheat and double reheat was conducted.The results showed that,under 1 000 MW unit load condition,compared with the turbine running with single reheat,the heat consumption rate of that running with double reheat decreased by 1.26%,about 92kJ/(kW·h)lower;the coal consumption for power supply decreased by 3.47g/(kW·h)and the unit net efficiency increased by 0.57%.

关 键 词:超超临界 1000 MW机组 二次再热 热耗率 机组净效率 

分 类 号:TK212.+4[动力工程及工程热物理—动力机械及工程] TK262

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象