摘 要:利用分光光度计,分别测试窗两片玻璃和百叶的透射与反射光谱曲线,再导入遮阳模拟软件W1NDOW6,对内置百叶一体化遮阳窗遮阳系数进行了模拟计算。然后利用上海建科院的人工模拟光源的遮阳测试试验台对窗的遮阳系数进行了实验测定。试验结果表明:内置百叶一体化遮阳窗有很好的遮阳效果,遮阳系数实测值为0.19,模拟值为0.18,相对误差为5.3%,模拟计算的准确性得到了验证。因此可以结合采用分光光度计和遮阳模拟软件WINDOW6的方法来测试内置百叶一体化遮阳窗的遮阳系数。The spectrophotometer was used to test the transmission and reflection spectra of two pieces of glass and the shutter of the window,and then imported the spectra to shade simulation software WIND0W6 to calculate the shading coefficient of the sealed insulating glass unit with Venetian blinds.The shading coefficient was also tested with experimental study which based on artificial light sources which was developed by Shanghai Research Institute of Building Science.Test results show that the sealed insulating glass unit with shutter inside has a good performance on shading coefficient which measured value was 0.19,simulation value was 0.18,and the relative error was 5.2%.The accuracy of simulation has been verified,the spectrophotometer and shade simulation software WINDOW6 can be combined to test the shading coefficient of the sealed insulating glass unit with Venetian blinds.
关 键 词:内置百叶一体化遮阳窗 遮阳系数 模拟计算 实验研究