摘  要:The paper proposes an approach to transmit electric power system dynamics in the SCADA. With the prevalent application of digital substation automation system, it is feasible for the remote terminal units (RTUs) to collect phasors within a substation. However, limited communication capacity remains the bottleneck that prevents SCADA from transmitting system dynamics. This paper proposes to compress dynamics data with curve fitting in the RTUs and reconstruct the dynamics in the SCADA server for reducing communication demand. Dispatchers in the control center can thus get system dynamics with a delay of several seconds. Simulation result shows that for a power system under disturbance with short-circuit that once occurred and was cleared, the SCADA can approximate the original dynamics with satisfying precision using limited degree polynomial fitting. The approach is highly scalable and adaptable, and can be implemented on existing communication infrastructure with a few software modifications. The approach has extensive application potential.The paper proposes an approach to transmit electric power system dynamics in the SCADA. With the prevalent application of digital substation automation system, it is feasible for the remote terminal units (RTUs) to collect phasors within a substation. However, limited communication capacity remains the bottleneck that prevents SCADA from transmitting system dynamics. This paper proposes to compress dynamics data with curve fitting in the RTUs and reconstruct the dynamics in the SCADA server for reducing communication demand. Dispatchers in the control center can thus get system dynamics with a delay of several seconds. Simulation result shows that for a power system under disturbance with short-circuit that once occurred and was cleared, the SCADA can approximate the original dynamics with satisfying precision using limited degree polynomial fitting. The approach is highly scalable and adaptable, and can be implemented on existing communication infrastructure with a few software modifications. The approach has extensive application potential.

关 键 词:SCADA WAMS (wide area measurement system) POLYNOMIAL FITTING SYSTEM dynamics 

分 类 号:TM76[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象