The influence of mechanical loading on osseointegration:an animal study  被引量:3

The influence of mechanical loading on osseointegration:an animal study

在线阅读下载全文

作  者:FAN YuBo1,XIU KaiHua1,DONG Xiang2 & ZHANG Ming2 1 School of Biological Science and Medical Engineering,Beihang University,Beijing 100083,China 2 Department of Health Technology and Informatics,The Hong Kong Polytechnic University,Hong Kong,China 

出  处:《Science China(Life Sciences)》2009年第6期579-586,共8页中国科学(生命科学英文版)

基  金:Supported by the National Natural Science Foundation of China (Grant Nos. 30370376,10529202 and 10672015)

摘  要:Osseointegration of implant provides a stable support for the prosthesis under functional loads.The timing of loading is a critical parameter that can govern the success of the osseointegration of implant.However,it is not clear whether the early loading can affect the success of osseointegration,or whether the no-loading healing period can be shortened.This paper presents an animal study conducted to investigate how external loads influence the osseointegration at the initial stage of healing.Titanium implants were inserted into the goat tibia laterally,and different axial loadings were applied to the im-plants in 4 weeks after surgery.After the 2 weeks period of early loading,animals were sacrificed and the tibia bones with the implants were cut off from the bodies.Then mechanical test was employed to find out the differences in the pull-out force,and shear strength at the bone-implant interface between the non-loaded and the loaded implants.The implant-bone interfaces were analyzed by histomor-phometric method,SEM(scanning electron micrograph) and EDS(energy density spectrum).The re-sults indicated that the bone-implant interface did not well integrate 4 weeks after surgery,and the fi-brous tissue could be found at the interfaces of the specimens without loadings.While the results of loaded specimens with 10 N axial force showed that that parts of the interface were well integrated,indicating that the early mild loading may play a positive role in the process of the osseointegration.The results support that a certain range of external loading would influence the process of osseointe-gration,and appropriate mechanical loading can be applied to shorten the osseointegration period after surgery.Osseointegration of implant provides a stable support for the prosthesis under functional loads.The timing of loading is a critical parameter that can govern the success of the osseointegration of implant.However,it is not clear whether the early loading can affect the success of osseointegration,or whether the no-loading healing period can be shortened.This paper presents an animal study conducted to investigate how external loads influence the osseointegration at the initial stage of healing.Titanium implants were inserted into the goat tibia laterally,and different axial loadings were applied to the im-plants in 4 weeks after surgery.After the 2 weeks period of early loading,animals were sacrificed and the tibia bones with the implants were cut off from the bodies.Then mechanical test was employed to find out the differences in the pull-out force,and shear strength at the bone-implant interface between the non-loaded and the loaded implants.The implant-bone interfaces were analyzed by histomor-phometric method,SEM(scanning electron micrograph) and EDS(energy density spectrum).The re-sults indicated that the bone-implant interface did not well integrate 4 weeks after surgery,and the fi-brous tissue could be found at the interfaces of the specimens without loadings.While the results of loaded specimens with 10 N axial force showed that that parts of the interface were well integrated,indicating that the early mild loading may play a positive role in the process of the osseointegration.The results support that a certain range of external loading would influence the process of osseointe-gration,and appropriate mechanical loading can be applied to shorten the osseointegration period after surgery.

关 键 词:OSSEOINTEGRATION IMPLANT ANIMAL model HISTOLOGY PULL-OUT test 

分 类 号:R68[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象