Design and cold test of S-BAND cavity BPM for HLS  被引量:1

Design and cold test of S-BAND cavity BPM for HLS

在线阅读下载全文

作  者:LUO Qing SUN BaoGen JIA QiKa HE DuoHui FANG Jia 

机构地区:[1]National Synchrotron Radiation Laboratory,School of Nuclear Science and Technology,University of Science and Technology of China,Hefei 230029,China

出  处:《Science China(Physics,Mechanics & Astronomy)》2011年第S2期292-295,共4页中国科学:物理学、力学、天文学(英文版)

基  金:supported by the National Natural Science Foundation of China (Grant Nos. 10875117 and 11005106);National "985 Project" (Grnat No. 173123200402002);China Postdoctoral Science Foundation (Grant No. 20100470853);"the Fundamental Research Funds for the Central Universities"

摘  要:An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.

关 键 词:CAVITY BPM RE-ENTRANT cut-through waveguide cold test wire scanning resolution CROSS-TALK 