A customized model for 3D human segmental kinematic coupling analysis by optoelectronic stereophotogrammetry  被引量:1

A customized model for 3D human segmental kinematic coupling analysis by optoelectronic stereophotogrammetry

在线阅读下载全文

作  者:ZHAO GuoRu REN Lei TIAN LiMei QIAN ZhiHui WANG Lei REN LuQuan 

机构地区:[1]Institute of Biomedical and Health Engineering,Shenzhen Institutes of Advanced Technology,Chinese Academy of Sciences,Shenzhen 518055,China [2]Key Laboratory for Biomedical Informatics and Health Engineering,Chinese Academy of Sciences,Shenzhen 518055,China [3]School of Mechanical,Aerospace and Civil Engineering,University of Manchester,Manchester M601QD,UK [4]Key Laboratory of Bionic Engineering(Ministry of Education),Jilin University,Changchun 130022,China

出  处:《Science China(Technological Sciences)》2010年第11期2947-2953,共7页中国科学(技术科学英文版)

基  金:supported partially by the National Natural Science Foundation of China (Grant Nos 50635030, 60932001 and 61072031);the National Basic Research Program of China ("973" Program) (Grant No 2010CB732606);the Knowledge Innovation Program of the Chinese Academy of Sciences;supported by the China Scholarship Council (CSC) and China Postdoctoral Project

摘  要:The study of three-dimensional human kinematics has significant impacts on medical and healthcare technology innovations. As a non-invasive technology, optoelectronic stereophotogrammetry is widely used for in-vivo locomotor evaluations. However, relatively high testing difficulties, poor testing accuracies, and high analysis complexities prohibit its further employment. The objective of this study is to explore an improved modeling technique for quantitative measurement and analysis of human locomotion. Firstly, a 3D whole body model of 17 rigid segments was developed to describe human locomotion. Subsequently, a novel infrared reflective marker cluster for 17 body segments was constructed to calibrate and record the 3D segmental position and orientation of each functional body region simultaneously with high spatial accuracy. In addition, the novel calibration procedure and the conception of kinematic coupling of human locomotion were proposed to investigate the segmental functional characteristics of human motion. Eight healthy male subjects were evaluated with walking and running experiments using the Qualisys motion capture system. The experimental results demonstrated the followings: (i) The kinematic coupling of the upper limbs and the lower limbs both showed the significant characteristics of joint motion, while the torso motion of human possessed remarkable features of segmental motion; (ii) flexion/extension was the main motion feature in sagittal plane, while the lateral bending in coronal plane and the axial rotation in transverse plane were subsidiary motions during an entire walking cycle regarding to all the segments of the human body; (iii) compared with conventional methods, the improved techniques have a competitive advantage in the convenient measurement and accurate analysis of the segmental dynamic functional characteristics during human locomotion. The modeling technique proposed in this paper has great potentials in rehabilitation engineering as well as ergonomics and biomimetic engineeringThe study of three-dimensional human kinematics has significant impacts on medical and healthcare technology innovations. As a non-invasive technology, optoelectronic stereophotogrammetry is widely used for in-vivo locomotor evaluations. However, relatively high testing difficulties, poor testing accuracies, and high analysis complexities prohibit its further employment. The objective of this study is to explore an improved modeling technique for quantitative measurement and analysis of human locomotion. Firstly, a 3D whole body model of 17 rigid segments was developed to describe human locomotion. Subsequently, a novel infrared reflective marker cluster for 17 body segments was constructed to calibrate and record the 3D segmental position and orientation of each functional body region simultaneously with high spatial accuracy. In addition, the novel calibration procedure and the conception of kinematic coupling of human locomotion were proposed to investigate the segmental functional characteristics of human motion. Eight healthy male subjects were evaluated with walking and running experiments using the Qualisys motion capture system. The experimental results demonstrated the followings: (i) The kinematic coupling of the upper limbs and the lower limbs both showed the significant characteristics of joint motion, while the torso motion of human possessed remarkable features of segmental motion; (ii) flexion/extension was the main motion feature in sagittal plane, while the lateral bending in coronal plane and the axial rotation in transverse plane were subsidiary motions during an entire walking cycle regarding to all the segments of the human body; (iii) compared with conventional methods, the improved techniques have a competitive advantage in the convenient measurement and accurate analysis of the segmental dynamic functional characteristics during human locomotion. The modeling technique proposed in this paper has great potentials in rehabilitation engineering as well as ergonomics and biomimetic engineering

关 键 词:human movement analysis in-vivo skeletal system kinematics calibration technique kinematic coupling 

分 类 号:R319[医药卫生—基础医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象