检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:CUI Xin1,FU YingZi1,2,LI MiaoSi1,CHEN Min2,HE Xuan1,LIU XiaoHua1 & FENG XiaoMing1 1Key Laboratory of Green Chemistry & Technology,Ministry of Education College of Chemistry,Sichuan University,Chengdu 610064,China 2Key Laboratory of Luminescence and Real-Time Analysis,Ministry of Education College of Chemistry and Chemical Engineering,Southwest University,Chongqing 400715,China
出 处:《Science China Chemistry》2010年第1期257-262,共6页中国科学(化学英文版)
基 金:support from the National Natural Science Foundation of China (Grant Nos. 20732003 & 20972128)
摘 要:L-Thiazolidine-4-carboxylic acid monolayer was prepared on gold electrodes through the self-assembly approach.Such novel thioether-based monolayer could efficiently preconcentrate Cu2+,which provided a simple,stable and reproducible method for the determination of Cu2+.The modified electrodes were stable enough to be continuously used for one week(more than 30 times regeneration) with lower than 10% decrease in the response.They retained their initial activity for more than one month if used once a day.The calibration curve was linear for Cu2+ from 0.6 to 158.8 μg L?1 with a detection limit of 0.38 μg L?1.The relative standard deviation was 3.2% for a series of six successive measurements.The proposed method was applied in the determination of Cu2+ in mineral water and human hair samples.L-Thiazolidine-4-carboxylic acid monolayer was prepared on gold electrodes through the self-assembly approach.Such novel thioether-based monolayer could efficiently preconcentrate Cu2+,which provided a simple,stable and reproducible method for the determination of Cu2+.The modified electrodes were stable enough to be continuously used for one week(more than 30 times regeneration) with lower than 10% decrease in the response.They retained their initial activity for more than one month if used once a day.The calibration curve was linear for Cu2+ from 0.6 to 158.8 μg L?1 with a detection limit of 0.38 μg L?1.The relative standard deviation was 3.2% for a series of six successive measurements.The proposed method was applied in the determination of Cu2+ in mineral water and human hair samples.
关 键 词:L-thiazolidine-4-carboxylic acid COPPER IONS gold electrode THIOETHER MONOLAYER
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112