摘 要:2008年5月12日四川发生8.0级大地震,造成地处江油的某水泥厂各种通廊结构发生不同程度的损坏,再加上部分结构年久失修,材料逐渐老化,构件开裂、钢筋锈蚀、混凝土剥落及碳化,严重影响安全生产。结合厂区通廊结构的检测鉴定结果,对受损结构构件的加固方法进行逐一分析,详细讨论了结构抗震缝处理、构件损伤加固处理以及结构的整体性和构造性加强、提出具体的加固方法和措施,为类似结构的震后鉴定和加固设计提供设计参考。The corridors of a cement factory were damaged in different levels after the earthquake happened in May 12th,2008 in Jiangyou,In addition,with the structure gradually aging,members cracking,steel corrosion,concrete spalling and carbonation,serious security issues were caused in production.Based on the detection and appraisal results of the concrete corridors,reinforcement measures analysis were made for the damage structure and structure members.Take into account the treatments of seismic joints,damaged structural members,strengthening of structural integrity and conformation measures,the detailed reinforcement measures were presented as reference design for similar structures after earthquake.