Design of low-energy building and energy consumption analyses  被引量:1

Design of low-energy building and energy consumption analyses

在线阅读下载全文

作  者:刘鸣 陈滨 范悦 朱佳音 索健 

机构地区:[1]School of Architecture and Fine Art,Dalian University of Technology [2]School of Civil and Hydraulic Engineering,Dalian University of Technology

出  处:《Journal of Central South University》2009年第S1期239-243,共5页中南大学学报(英文版)

基  金:Project(50778032) supported by the National Natural Science Foundation of China;Project(2006BAA04B04) supported by the National Science and Technology Pillar Program During 11th-Five-year Plan of China;Project(JN-200912) supported by Open Fund of Key Laboratory in Liaoning Province’s Universities,China

摘  要:In China,a new "Design standard for energy efficiency of residential buildings (for cold region)" was introduced in 2006. In this new standard,more high level insulation of the building envelope is required,yearly energy requirement for heating must be less than 55 kWh/(m2·a)(regarded as a low-energy house). The new attempt was carried out in the process of architecture design with an evaluation on energy consumption of the building. The design plan was brought forward and compared. PHPP software from German was applied to calculate energy consumption of the passive residential building. The optimum design planning was discussed and model of passive house suited to China's national conditions were attempted. The compactness,solar air collector and the window-wall ratio have essential influence on the energy consumption of buildings. The annual heat demands for the buildings with the window-wall ratio 0.35 and 0.50 are 48 kWh/(m2·a) and 46 kWh/(m2·a),respectively. The yearly auxiliary heat of building with the wall-mounted solar air collectors and the window-wall ratio 0.35 is just 4.8 kWh/(m2·a).In China,a new 'Design standard for energy efficiency of residential buildings (for cold region)' was introduced in 2006. In this new standard,more high level insulation of the building envelope is required,yearly energy requirement for heating must be less than 55 kWh/(m2·a)(regarded as a low-energy house). The new attempt was carried out in the process of architecture design with an evaluation on energy consumption of the building. The design plan was brought forward and compared. PHPP software from German was applied to calculate energy consumption of the passive residential building. The optimum design planning was discussed and model of passive house suited to China's national conditions were attempted. The compactness,solar air collector and the window-wall ratio have essential influence on the energy consumption of buildings. The annual heat demands for the buildings with the window-wall ratio 0.35 and 0.50 are 48 kWh/(m2·a) and 46 kWh/(m2·a),respectively. The yearly auxiliary heat of building with the wall-mounted solar air collectors and the window-wall ratio 0.35 is just 4.8 kWh/(m2·a).

关 键 词:low ENERGY HOUSE ENERGY CONSUMPTION DESIGN PHPP software PASSIVE HOUSE 

分 类 号:TU111.4[建筑科学—建筑理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象