Design of slow extraction system for therapy synchrotron  

Design of slow extraction system for therapy synchrotron

在线阅读下载全文

作  者:张金泉 宋明涛 魏宝文 

机构地区:[1]Institute of Modern Physics, CAS

出  处:《Chinese Physics C》2009年第S2期30-32,共3页中国物理C(英文版)

基  金:Supported by Key Equipment R & D Fund of CAS (0713040YZ0)

摘  要:Based on the optimized design of the lattice for therapy synchrotron and considering the requirement of radiation therapy, the third order resonant extraction is adopted. Using the momentum-amplitude selection method, the extraction system is designed and optimized. An extraction efficiency of more than 97% and a momentum spread less than 0.11% are obtained.Based on the optimized design of the lattice for therapy synchrotron and considering the requirement of radiation therapy, the third order resonant extraction is adopted. Using the momentum-amplitude selection method, the extraction system is designed and optimized. An extraction efficiency of more than 97% and a momentum spread less than 0.11% are obtained.

关 键 词:slow extraction third order resonance SYNCHROTRON 

分 类 号:TL503[核科学技术—核技术及应用]

 