检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南京铁道职业技术学院,江苏南京210015 [2]湖南大学土木工程学院,湖南长沙410082
出 处:《湖南大学学报(自然科学版)》2009年第S2期27-30,共4页Journal of Hunan University:Natural Sciences
基 金:国家863项目"复合冷凝热泵热水空调及冷热源新技术研究"(2006AA05Z229)
摘 要:华东地区是亚热带气候,地源热泵的埋管换热效果等参数与北方地区不同,采用实地测量的方法研究了地源热泵系统在华东地区性能.结果表明,100 m单U型埋地管的每米孔深换热量为56 W/m,地源热泵系统全年总换热量为3 395 000.1 kWh,COP达到3.8,两年可收回系统初投资,是节能、经济的热泵系统.East China is in subtropical climate region.Heat transfer effect and other parameters of ground-source heat pump pipe are different from those of North China.Based on field measurement,the performances of ground-source heat pump system in East China were analyzed.The results showed 100-meter single U-tube heat transfer was 56 W/m for each hole,the annual heat transfer of the ground-source heat pump system was 3 395 000.1 kWh,the COP reached 3.8,and the initial investment of the system could recover in two years.So this system was energy-efficient and economical heat pump system.
分 类 号:TU831.3[建筑科学—供热、供燃气、通风及空调工程]