检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]神华国华(北京)电力研究院有限公司,北京100069 [2]神华国华太仓发电有限公司,江苏215433
出 处:《神华科技》2009年第1期51-54,共4页Shenhua Science and Technology
摘 要:针对一台因高温过热器氧化皮大量脱落发生爆管事故的600MW超临界锅炉,进行了炉内分级送风比例对于高温过热器热偏差影响的数值模拟计算和现场试验研究。模拟计算结果表明炉内分级送风对于减小炉膛上部切圆直径、降低水平烟道内的热偏差作用明显;现场试验结果表明,适度增大炉内分级送风比例使高温过热器管壁温度分布更均衡,峰值温度降低5℃~10℃,使受热面运行安全性得以提高。Aiming at a 600MW supercritical boiler in which tubes cracking of high-temperature superheater happened because of oxide skin on the inwall of tubes falling off,investigations on the effect of the ratio of staged air in the total air on heat transfer difference on its high-temperature superheater were carried out by numerical simulation and field test.The simulation results show that staged air can significantly reduce tangential circle diameter of upper parts of furnace and lower heat transfer difference of horizontal gas flue;The field test results show that the proper ratio of staged air in the total air can make tubes wall temperature distribution of high-temperature superheater uniform,and tubes’peak temperature lowered 5~10℃.Then safety in operation of heating surfaces can raise.
分 类 号:TK229.6[动力工程及工程热物理—动力机械及工程]