剖宫产术后立即放置FTCu220C-M和△TCu22OC比较研究  被引量:7

Fix-TCu 220C-M and Delta-TCu 220C Inserted Immediately during Cesarean Section; A Comparative Randomized Clinica Study.

在线阅读下载全文

作  者:钱丽娟[1] 刘惠娟[1] 刘映粦[1] 张志诚[2] 李敬之[2] 王惠茹 闫玉坤 胡云霞[3] 尚玉敏[3] 赵曰敏[4] 

机构地区:[1]天津医学院第二附属医院,300211 [2]天津医学院第一附属医院 [3]天津市中心妇产科医院 [4]天津市计划生育研究所

出  处:《中国计划生育学杂志》1994年第1期16-18,60,共4页Chinese Journal of Family Planning

摘  要:对400例妇女首次进行子宫下截横切口剖腹产胎盘娩出后立即随机放置Fix-Cu220C-M与ΔTCu220C各200例,进行前瞻性临床比较性研究。结果显示Fix-Cu220C-M的妊娠率低0.5%,脱落率2.2%较ΔTCu220C的10.5%显著低(P<0.01)。与IUD有关的继续存放净累积率Fix-IUD为94.8%,较Delta-IUD的86.4%显著高(P<0.01)。剖宫产后立即放置Cu220C-M是一种安全、高效、可接受的避孕措施。A comparative study of Fix-TCu 220C-M and the Delta-TCu 220C (△TCu220C, which were inserted immediately during cesarean section at lower uterine segment by transeverse incision. The experience of 400 acceptors (200 for each type of TCu IUD),who were for the first time having such operation, was analyzed by life table technique. The pregnancy rate was 0. 5%by the end of 30 months.The expulsion rate of Fix-TCu 220-M and TCu220C were 2. 2% and 10. 5% , respectively. The former was significantly lower than the latter (P<0. 01). Removal for medical reasons were 2. 5% and 2. 6% , respectively. The net cumulative continuation rate related to IUD use were 94. 8% for Fix-IUD and 86. 4% for Delta-IUD. There was a significant difference between them (P<0. 01). The results suggested that the Fix-TCu 220C-M inserted immediately during cesarean section after placenta delivery is a safe,highly a effective and acceptable contraceptive method.

关 键 词:Fix-Cu220C-M TCU220C 

分 类 号:R169.41[医药卫生—公共卫生与预防医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象