PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY  

PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

在线阅读下载全文

作  者:陈农 张玉奎 卢佩章 

机构地区:[1]National Chromatographic R. & A. Center, Dalian Institute of Chemical Physics,Academia Sinica, Dalian 116011, PRC

出  处:《Science China Chemistry》1992年第12期1425-1433,共9页中国科学(化学英文版)

摘  要:The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.The interaction index c which was derived from the fundamental retention equationlogk' =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.

关 键 词:peak identification REVERSED-PHASE high-performance liquid chromatography interaction INDEX c HYDROPHOBIC INDEX α LINEAR α-α PLOTS on column PAIRS LINEAR α-c relationship structural related compounds 

分 类 号:O6[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象