Determination of Trace Silver( Ⅰ ) in Basic Aqueous Solution by Electrochemiluminescence of a New Reagent 6-(2-Hydroxy-4-Diethylaminophenylazo)-2,3-Dihydro-1,4-Phthalazine-1,4-Dione  

Determination of Trace Silver( Ⅰ ) in Basic Aqueous Solution by Electrochemiluminescence of a New Reagent 6-(2-Hydroxy-4-Diethylaminophenylazo)-2,3-Dihydro-1,4-Phthalazine-1,4-Dione

在线阅读下载全文

作  者:An Jingru Lin Jinming (Department of Chemistry, Fuzhou University, Fuzhou) To whom correspondence should be addressed. 

出  处:《Chemical Research in Chinese Universities》1991年第1期32-36,共5页高等学校化学研究(英文版)

摘  要:The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ourselves. Trace amounts of silver ( Ⅰ ) shows a significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the solution. The linear relationship between the light intensity and the concentration of silver( Ⅰ ) occurs in the range of 5. 0×10-8 to 3. 0×10-8 mol/L Ag(Ⅰ ) in a medium of KOH-KCl-HDEA (pH= 12. 8). The detection limit of the method is 2. 0×10-8 mol/LAg( Ⅰ ), and the r. s. d. for 1.0×10-7 mo)/L Ag ( Ⅰ ) is 5%. Of 21 metal ions concerned, only nickel( Ⅱ ), cerium( Ⅳ ) and cobalt( Ⅱ ) interfere the silver detection seriously; Ⅰ and Br also have some interference.The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ourselves. Trace amounts of silver ( Ⅰ ) shows a significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the solution. The linear relationship between the light intensity and the concentration of silver( Ⅰ ) occurs in the range of 5. 0×10-8 to 3. 0×10-8 mol/L Ag(Ⅰ ) in a medium of KOH-KCl-HDEA (pH= 12. 8). The detection limit of the method is 2. 0×10-8 mol/LAg( Ⅰ ), and the r. s. d. for 1.0×10-7 mo)/L Ag ( Ⅰ ) is 5%. Of 21 metal ions concerned, only nickel( Ⅱ ), cerium( Ⅳ ) and cobalt( Ⅱ ) interfere the silver detection seriously; Ⅰ and Br also have some interference.

关 键 词:ELECTROCHEMILUMINESCENCE Reagent Silver 6 ( 2 Hydroxy-4 diethy laminophenylazo)-2 3-dihydro-1 4-phthalazine 1  4-dione 

分 类 号:O6[理学—化学]

 