350 MW超临界机组甩负荷试验锅炉侧参数控制  被引量:1

Parameters Control of Boiler in Load Rejection Test of Supercritical 350 MW Coal-fired Unit

在线阅读下载全文

作  者:黄辉[1] 刘刚[1] 杨杰[1] 

机构地区:[1]湖北省电力公司电力科学研究院,湖北武汉430077

出  处:《湖北电力》2013年第2期52-54,共3页Hubei Electric Power

摘  要:结合国电青山热电有限公司新建2×350MW超临界热电联产燃煤机组甩50%负荷和100%负荷试验,重点从锅炉侧主、再蒸汽参数变化、锅炉给水流量变化及炉膛负压变化角度,探讨甩负荷试验过程中避免锅炉熄火的参数控制方法,提出了操作建议。On the basis of the successful experience in 50% load rejection and 100% load rejection tests of 2×350 MW supercritical coal-fired power and thermal units in Hubei Guodian Qingshang Co-generation Co.Ltd.,the control measures for avoiding the flame extinction of the boiler were discussed.The focus was put on the analysis about the changes in the load rejection tests process,such as the superheat steam and reheat steam parameters,the feed water flow of the boiler,and the pressure in the furnace.At last,several significantly operating suggestions were concluded.

关 键 词:超临界燃煤机组 热电联产 甩负荷试验 参数控制 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 