检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周兰欣[1] 林湖[1] 胡学武[2] 郭锦鹏[1] 张淑侠[1]
机构地区:[1]华北电力大学动力系,河北保定071003 [2]天津大港电厂,天津300000
出 处:《汽轮机技术》2004年第3期170-172,共3页Turbine Technology
摘 要:对凝汽器传热端差的各个主要影响因素及它们之间的关系进行分析,解释了有关表达式及相关概念难以理解的问题,利用不同容量级机组的有关参数进行计算,并联系工程实际,进一步验证分析方法及结果的正确性。该结果不仅适用于凝汽器端差的分析,对于其它换热器的传热端差计算同样具有实用意义。The temperature difference of condenser is a very important parameter in power plant and is not understood clearly in research of theory and practice. Based on the analysis of the factors of condenser's temperature difference and the relation among themselves, some beyond understanding questions of the expression and conception are made clear. According to the calculation (based on the design parameters of different capacity level) and the engineering facts, the analysis and the result are proved again. The result is the same with others heat exchanger.
分 类 号:TK264[动力工程及工程热物理—动力机械及工程]