电法勘探中万用表测接地电阻的探讨  被引量:2

Study of Measuring Earth Resistance Through Multimeter in Electric Method Prospecting

在线阅读下载全文

作  者:徐剑波[1] 吴信民[1] 黎正根[1] 曹俊昌[1] 陈峰[1] 叶兴超 

机构地区:[1]东华理工大学,江西抚州344000

出  处:《东华理工大学学报(自然科学版)》2013年第S1期53-56,共4页Journal of East China University of Technology(Natural Science)

基  金:国家自然科学基金(41174107);江西省自然科学基金(2010GZW003)

摘  要:在电法勘探中,常需要测量接地电极的接地电阻。测量接地电阻用万用表进行测量时,极化电位会影响到测量的准确性。从极化电位机理和万用表电阻测量原理出发,分析了极化电位给接地电阻测量带来的影响,同时讨论了改善结果的方案。It is necessary to measure the earth resistance of grounding electrode in electric method prospecting. When using multimeter to measure the earth resistance,the existence of polarization potential will affect the accuracy of measurements in theory. Based on the mechanism of polarization potential and the principle of measuring resistance through multimeter,it is studied that the influence to the measurements of earth resistance caused by the polarization potential,and then it is discussed that the improvement scheme measure erath resistance.

关 键 词:电法勘探 接地电阻 万用表 金属电极 极化电位 

分 类 号:P631.3[天文地球—地质矿产勘探]

 