检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曹万林[1] 徐萌萌[1] 董宏英[1] 武海鹏[1] 王立长
机构地区:[1]北京工业大学建筑工程学院,北京100124 [2]大连市建筑设计研究院有限公司,辽宁大连116021
出 处:《工程力学》2015年第6期99-108,123,共11页Engineering Mechanics
基 金:国家自然科学基金项目(51178010);国家自然科学基金创新研究群体项目(51421005)
摘 要:基于某超高层建筑五边形钢管混凝土巨型柱,研究了不同截面构造五边形钢管混凝土巨型柱的轴压性能。进行了3个五边形钢管混凝土巨型柱试件的单向重复轴压性能试验,试件分别为设钢筋笼单腔体截面、无钢筋笼四腔体截面和设钢筋笼四腔体截面。得到了轴力-位移骨架曲线,分析了损伤破坏过程、残余变形和弹塑性耗能性能,提出了适用的极限承载力计算方法。用ABAQUS软件进行了有限元模拟,分析了截面构造参数(腔体数、有无钢筋笼)对试件受力性能的影响,计算结果与试验符合较好。研究表明:四腔体截面试件与单腔体截面试件相比,承载力和延性明显提高,残余变形较小,耗能能力较强;四腔体试件中腔体内设钢筋笼的试件与不设钢筋笼的试件相比,承载力、延性、耗能能力进一步提高,残余变形减小。四腔体设钢筋笼的五边形钢管混凝土巨型柱综合抗压性能良好,可用于超高层结构设计。Based on the pentagonal concrete filled steel tubular(CFST) mega columns of a super high-rise building, axial compressive behavior of pentagonal CFST mega columns with different cross-sections and detailing were studied. Monotonic cyclic loading tests of 3 pentagonal CFST mega column specimens were conducted under axial compression. 3 specimens were respectively: a single-caved section with a reinforcement cage, a quadruple-caved section without reinforcement cage and a quadruple-caved section with reinforcement cages. Axial force-deformation curves were obtained. The failure mechanisms, residual deformation and elastic-plastic energy dissipation capacities were analyzed. Methods for calculating the ultimate bearing capacity of CFST mega columns were proposed. Finite element simulations are carried out based on ABAQUS for analyzing the effects of cross-sectional and detailing parameters, including the number of cavities and the presence of reinforcement cages on member behavior. The simulation results agree well with the test results. It is concluded that quadruple-caved sections have greatly increased the bearing capacity and ductility with less residual deformation and better energy dissipation capacity compared with single-caved sections. Additionally, quadruple-caved sections with reinforcement cages have further increased the bearing capacity, ductility, and the energy dissipation capacity with even less residual deformation compared with quadruple-caved sections without reinforcement cages. Pentagonal CFST mega columns with quadruple-caved sections and reinforcement cages have comprehensively good compressive behavior, which can be used in the design of super high-rise buildings.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117