Si-PIN探测器中子直照灵敏度研究  

Study on the neutron sensitivity of Si-PIN detector to direct radiations

在线阅读下载全文

作  者:张国光[1] 黄龙生[1] 张前美[1] 欧阳晓平[1] 宋纪文[1] 张显鹏[1] 周祖英[2] 

机构地区:[1]西北核技术研究所,陕西西安710024 [2]中国原子能科学研究院核物理所,北京102413

出  处:《核电子学与探测技术》2004年第4期373-375,共3页Nuclear Electronics & Detection Technology

摘  要:介绍了利用K600中子发生器进行Si-PIN探测器灵敏度标定的实验方法,并在实验中测出了Si-PIN探测器对14MeV中子的直照灵敏度。同时,利用MCNP模拟程序对Si-PIN探测器不同能量的中子直照灵敏度进行了理论计算,实验灵敏度处理结果和理论计算值较为一致。In this paper, the experimental method of sensitivity calibration for Si-PIN detector on K-600 neutron generator is introduced in details. The experimental sensitivity of Si-PIN detector to direct neutron radiations is presented as well.Meanwhile,the theoretical values of Si-PIN detectors' sensitivity at several specific neutron energies are also calculated by using MCNP code. The results show that the theoretical values are in good agreement with the experimental data.

关 键 词:SI-PIN探测器 中子直照灵敏度 中子发生器 灵敏度标定 MCNP程序 

分 类 号:TL816[核科学技术—核技术及应用]

 