检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:林培喜[1] 李德豪[1] 周锡堂[1] 陈少华[1]
机构地区:[1]茂名学院化工学院,茂名525000
出 处:《理化检验(化学分册)》2004年第7期390-392,共3页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
摘 要:采用微波消解光度法测定炼油污水的化学需氧量,用炼油污水(回流法准确测定其COD值)作为COD的标准溶液制作工作曲线、或求取回归方程的新方法。CODCr的测定范围为90~2000mg·L-1。与用邻苯二甲酸氢钾作为标准的CODCr值求得的回归方程相比,其值更接近回流法。方法具有设备简单、操作方便、分析时间短、精密度高、且快速、成本低、二次污染少等优点,值得在石油化工企业中推广应用。The accurate value of COD_(Cr) of the refinery waste water was determined preliminarily by the conventional refluxing method, and used as standard instead of the potassium hydrogen o-phthalate standard, in the preparation of standard working curve or in the calculation of the linear regression equation. The absorbance of the sample solution (or the standard solution) after digestion was measured photometrically at 600nm for its trivalent chromium content. The power used in the microwave heating of sample (or standard) solution is 720W and the time taken for the digestion is 12min. The range of determination of COD_(Cr) of this method is from 90 to 2 000mg·L^(-1). It was found that results of COD_(Cr) obtained by this method are more closer to the results obtained by the refluxing method as compared with the method using o-phthalate as standard. It was shown by the results obtained, that the present method is more profitable and feasible to be used in the monitoring of waste water from petro-refinery.