检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱俊杰[1] 卢宗桂 陈莉[1] 郑建斌[1] 高鸿[1] 赵守孝
机构地区:[1]南京大学化学系,南京210008 [2]军事医学科学院毒物药物研究所
出 处:《分析化学》1993年第8期939-941,共3页Chinese Journal of Analytical Chemistry
基 金:国家自然科学基金
摘 要:本文运用简易示波伏安法成功地进行了药物滴定分析,测定了两种新药胃复康及氢溴酸苯甲托品,获得了满意的结果。这种方法克服双池伏安法仪器复杂等缺点,使用一个电解池和一个很简单的线路也可获得示波伏安图。它能部分地扣除充电电流,终点时峰形变化敏锐。Two new drugs called benactyzini hydrochloridum and benzatropini hydrobromidum were determined by a simple oscillographic voltammetry with satisfactory results. The new method overcomes some faults in oscillographic voltammetry of using two electrolytic cells. The if-E curve can be obtained by using an electrolytic cell and a simple circuit. It can compensate some of charging current of the electrical double layer. At end-point, the change of peak is sharp, so it can be widely applied to the titrimetric analysis of Pharmaceuticals.
分 类 号:TQ460.72[医药卫生—药物分析学]