Experimental Investigation of Spray Evaporation in Turbulent Flow in Countercurrent Humidifier  

Experimental Investigation of Spray Evaporation in Turbulent Flow in Countercurrent Humidifier

在线阅读下载全文

作  者:王玉璋 刘永文 翁史烈 

机构地区:[1]Key Lab. for Power Machinery and Eng. of the Ministry of Education, Shanghai Jiaotong Univ.

出  处:《Journal of Shanghai Jiaotong university(Science)》2004年第1期19-25,共7页上海交通大学学报(英文版)

基  金:973 Key Develop Projectof the Ministry ofScience and Technology of China (No.G19990 2 2 3 0 3 )

摘  要:The process in the countercurrent humidifier of HAT cycle involves the evaporation of atomized liquids in a turbulent environment. To allow an optimization of such process and provide data for the validation of numerical calculation, the spray evaporation in a countercurrent air stream was studied experimentally. Measurements were taken for different flow parameters, such as airflow rate and liquid flow rate in order to provide reliable data. Phase-Doppler anemometry (PDA) was applied to obtain the spatial change of the droplet size spectrum in the flow field and to measure droplet size-velocity correlations. These local measured profiles of droplet mean velocities, velocity fluctuations and droplet mean diameters were obtained by averaging over all droplet size classes. Moreover, DualPDA signal processing allows accurate determination of the droplet mass flux and local concentration, from which the global evaporation rates could also be determined. These local temperature profiles were measured using the thermocouple and acquired by data acquisition system based on virtual instrument (VI) technology.The process in the countercurrent humidifier of HAT cycle involves the evaporation of atomized liquids in a turbulent environment. To allow an optimization of such process and provide data for the validation of numerical calculation, the spray evaporation in a countercurrent air stream was studied experimentally. Measurements were taken for different flow parameters, such as airflow rate and liquid flow rate in order to provide reliable data. Phase-Doppler anemometry (PDA) was applied to obtain the spatial change of the droplet size spectrum in the flow field and to measure droplet size-velocity correlations. These local measured profiles of droplet mean velocities, velocity fluctuations and droplet mean diameters were obtained by averaging over all droplet size classes. Moreover, DualPDA signal processing allows accurate determination of the droplet mass flux and local concentration, from which the global evaporation rates could also be determined. These local temperature profiles were measured using the thermocouple and acquired by data acquisition system based on virtual instrument (VI) technology.

关 键 词:spray phase-Doppler anemometer (PDA) turbulence EVAPORATION droplet velocity droplet size HUMIDIFIER 

分 类 号:P414.73[天文地球—大气科学及气象学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象