检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]中国建筑设计研究院,北京100044 [2]清华大学建筑设计研究院,北京100084
出 处:《给水排水》2004年第7期60-62,共3页Water & Wastewater Engineering
摘 要:针对生态建筑的建造模式及节约资源,减少污染,创造健康、舒适的办公、居住环境的建 造要求,以“生态优先”为原则,通过生态化设计,优化场地规划,改善热、光、声、风环境。以海淀温泉 生态办公区A座办公楼为例,介绍该工程满足生态建筑要求的给水排水系统设计。In answer to the construction requirements of ecological buildings model, energy saving, reduced pollution, and the creation of healthy and comfortable office and living environment, the site planning is optimized and the environment of heating, lighting, sound and wind is optimized by ecological design on the principle 'ecological priority'. It is taked A Building in the hot spring ecological office quarters, Haidian District, Beijing, for a example, presenting the design of the water supply and sewerage system, which satisfies the construction requirements of ecological buildings.