摘 要:介绍了通过连续电路处理的Rogowski线圈测量小电流的原理及其实现 ,并给出额定电流 0 2A时的试验结果 ,其精度达到 0 2级。Rogowski线圈的线性度好、无磁饱和、测量频率范围宽、结构简单 ,适应了电力系统在线测量、数字化继保、控制、故障诊断及电力系统光纤网的发展趋势。The merits of Rogowski coil are good linearity, no magnetism saturation, very large scope of measurement frequency and simple structure and so on. It makes Rogowski coil suitable to measurement on-line, digital relay, control in time, diagnoses of fault and measurement of slim current by circuit disposing. The basic theory and the realization is given, and the three applications are given. At last, the test results with rated current is 0.2 A, prove the precision to be grade 0.2.
关 键 词:ROGOWSKI线圈 测量 微小电流 应用