电站锅炉炉墙振动原因分析  被引量:8

CAUSE ANALYSIS OF FURNACE WALL VIBRATION FOR UTILITY BOILERS

在线阅读下载全文

作  者:丹慧杰[1] 刘家钰[1] 

机构地区:[1]国电热工研究院,陕西西安710032

出  处:《热力发电》2004年第8期41-42,共2页Thermal Power Generation

摘  要:通过对我国电站锅炉炉墙振动事例的分析 ,认为炉墙振动主要由流体动力学、燃烧动力学、炉膛压力波动频率与声学固有频率共振、炉墙刚性不足等原因引起 ;对解决和改善不同原因造成的锅炉炉墙振动提出了建议和对策 ,其对防止此类问题的发生有一定的借鉴作用。Through analysis of furnace-wall vibration cases for utility boilers in China, it is considered that the furnace-wall vibration is mainly caused by fluid dynamics, combustion dynamics, resonance of furnace pressure fluctuation frequency with acoustics’ natural frequency, as well as insufficient rigidity of the furnace wall. And recommendations and countermeasures have been put forward for boilers’ furnace wall vibration resulting from different causes, having certain reference role for preventing problems of this kind from occurring.

关 键 词:电站 锅炉炉墙 振动 膜式水冷壁 空气预热器 流体动力学 燃烧动力学 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 